Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
Add filters








Year range
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 511-515, 2022.
Article in Chinese | WPRIM | ID: wpr-956816

ABSTRACT

Objective:To provide a new morning check method for the output dose stability of the multileaf collimator (MLC) of the CyberKnife M6 (CK-M6) system.Methods:The CT images of a verification phantom with a size of 20 cm × 20 cm × 10 cm were transmitted into the Precision Treatment Plan ning System (ver. 1.1.1.1). The high-precision alignment between the accelerator output front and the fixed position of the phantom surface was achieved using the fiducial tracking method. A 10 cm × 10 cm radiation field was formed by the MLC and a DailyCheck plan with an output of 200 MU was designed. The repeatability, sensitivity, and accuracy of the DailyCheck plan were measured, and the CK-M6 system was continuously tested for one month using the artificial fixed method and the DailyCheck plan designed in this study. Results:The average and the standard deviation of 10 repeated measurements by the DailyCheck plan were 492.28 pC and 0.09, respectively, indicating good stability. There was a linear correlation between the measured values and the output dose, with a correlation coefficient of R2 > 0.999. Moreover, there was a position deviation of 2 mm between the phantom and the accelerator output front, and the result ant effect on the measured values was equivalent to a dose deviation caused by an output of 1.24 MU. The result from the continuous measurement of both the artificial fixed method and the DailyCheck plan fell within permissible limits, showing high consistency. Conclusions:The DailyCheck plan established through the fiducial tracking of a verification phantom can achieve the convenient, quick, and accurate daily detection of the output dose stability of the MLC of CK-M6. Therefore, this method can be widely applied in the clinical quality control of the CK-M6 system.

2.
Chinese Journal of Radiation Oncology ; (6): 55-58, 2022.
Article in Chinese | WPRIM | ID: wpr-932628

ABSTRACT

Objective:To investigate the safety and dose of 4D template (real-time adjustable angle template) in the treatment of advanced malignant tumors with 125I seeds. Methods:98 patients with advanced malignant tumors admitted to Department of Thoracic Surgery of Shaanxi Provincial Tumor Hospital were treated with 4D template-navigated radioactive 125I seed implantation from June 2018 to December 2019. Preoperative TPS plan, intraoperative optimization, postoperative verification of immediate dose and postoperative evaluation of implantation dose were performed. The treatment results were observed. Results:All 98 patients completed the seed implantation. The implantation dose of GTV of implantation site receiving external irradiation was (12 489±414) cGy and the dose of no external irradiation was (15 036±514) cGy. V 100% was 84.7%-94.1%, and 88.2%-93.7%. The implantation dose of CTV was (7 450±621) cGy, and (9 080±761) cGy. The quality of dose implantation was evaluated as: excellent in 89 cases (91%, 89/98), good in 7 cases (7%, 7/98), fair in 2 cases (2%, 2/98), and poor in 0 case, respectively. The symptom relief rate of patients with pain was 92%(36/39). The 1-and 2-year local control rates were 61%, 36% and 82%, 54% in patients treated with and without external irradiation, respectively. The difference was statistically significant ( P=0.02). The incidence rates of pneumothorax and hemoptysis were 19%(9/48) and 10%(5/48). No corresponding complications were observed in other parts of the patients. Conclusion:4D template-assisted 125I seed therapy is safe and effective for malignant tumors, and intraoperative adjustment of needle angle and dose optimization can realize the precise control of implantation dose.

3.
Chinese Journal of Clinical Oncology ; (24): 427-430, 2020.
Article in Chinese | WPRIM | ID: wpr-861591

ABSTRACT

Stereotactic body radiation therapy (SBRT) is a high-precision radiotherapy technology that provides high-dose and high-precision radiotherapy through less fractional irradiation. SBRT can significantly improve local control and survival rates in patients with hepatocellular carcinoma (HCC). SBRT can also be an effective and safe bridging therapy for patients awaiting liver transplantation. Moreover, recent studies have reported the potential effects of the combination of SBRT and immune checkpoint inhibitors. This article reviews the safety and efficacy of SBRT in the treatment of HCC, in anticipation of the future application of SBRT in combination with immunotherapy.

4.
Chinese Journal of Radiological Medicine and Protection ; (12): 926-930, 2019.
Article in Chinese | WPRIM | ID: wpr-800168

ABSTRACT

Objective@#To compare the dosimetrics of the plan target volume (PTV) and organs at risk (OARs) between two treatment planning approaches for patients with multiple brain metastases from non-small cell lung cancer on CyberKnife.@*Methods@#20 patients with multiple metastases from lung carcinoma were reviewed and analyzed, who had been treated by CyberKnife from December 2017 to December 2018. The CyberKnife stereotactic radiotherapy plans of the 20 cases were re-planed with single plan for multiple lesions and multiple plans per lesion. The dosimetry differences of PTV and OARs isodose disribution, conformity index (CI), total beam counts and total monitor units (MUs) were compared in the two types of plans.@*Results@#The two types of plans could satisfy over 95% PTV coverage of the prescription dose. The maximum and mean dose of normal brain adjacent to the PTV were reduced in multiple plan approach effectively. Moreover, the maximum and mean dose of OARs (brainstem) dropped by 1.62% and 5.57% (t=1.09, P<0.01) respectively. The number of treatment nodes and total MU declined by 4.63% (t=1.87, P<0.01)and 1.06% in multiple plan approach, which could significantly shorten the clinical treatment time. The differences in CI index between these two types of plans was of no statistical significance.@*Conclusions@#For patients with multiple brain metastases of similar diameter and volume from non-small cell lung cancer to be treated on CyberKnife, multiple plans per lesion could not only reduce dose to normal brain tissue and OARs, but also improve the treatment efficiency.

5.
Chinese Journal of Radiological Medicine and Protection ; (12): 926-930, 2019.
Article in Chinese | WPRIM | ID: wpr-824494

ABSTRACT

Objective To compare the dosimetrics of the plan target volume (PTV) and organs at risk (OARs) between two treatment planning approaches for patients with multiple brain metastases from non-small cell lung cancer on CyberKnife.Methods 20 patients with multiple metastases from lung carcinoma were reviewed and analyzed,who had been treated by CyberKnife from December 2017 to December 2018.The CyberKnife stereotactic radiotherapy plans of the 20 cases were re-planed with single plan for multiple lesions and multiple plans per lesion.The dosimetry differences of PTV and OARs isodose disribution,conformity index (CI),total beam counts and total monitor units (MUs) were compared in the two types of plans.Results The two types of plans could satisfy over 95% PTV coverage of the prescription dose.The maximum and mean dose of normal brain adjacent to the PTV were reduced in multiple plan approach effectively.Moreover,the maximum and mean dose of OARs (brainstem) dropped by 1.62% and 5.57% (t =1.09,P<0.01) respectively.The number of treatment nodes and total MU declined by 4.63% (t=1.87,P<0.01) and 1.06% in multiple plan approach,which could significantly shorten the clinical treatment time.The differences in CI index between these two types of plans was of no statistical significance.Conclusions For patients with multiple brain metastases of similar diameter and volume from non-small cell lung cancer to be treated on CyberKnife,multiple plans per lesion could not only reduce dose to normal brain tissue and OARs,but also improve the treatment efficiency.

6.
Chinese Journal of Radiological Medicine and Protection ; (12): 415-421, 2019.
Article in Chinese | WPRIM | ID: wpr-754983

ABSTRACT

Objective To evaluate the safety and effectiveness of ultra-hypofractionated stereotactic body radiotherapy in the treatment of prostate cancer.Methods A total of 26 patients with prostate cancer treated with Cyber-Knife from May 2010 to May 2018 were analyzed retrospectively.The median age of the patients was 69 years old (range,57 to 87).Ultra-hypofractionated radiotherapy was delivered in five fractions of 7.0-7.5 Gy for a total dose of 35.0-37.5 Gy.Androgen deprivation therapy (ADT) was administered in combination with the Cyber-Knife.The primary endpoints were radiation toxicity,PSA-response,local control and symptom alleviation,while the secondary endpoints were progression-free survival and overall survival.Results No graded ≥ 3 acute and late radiation toxicities occurred during follow-up.The acute toxicity of Grades 1 and 2 was 38.4% and 19.2%,while the late toxicity of Grades 1 and 2 was 30.8% and 3.8%,respectively.At a median follow-up of 22.44 months,for patients with localized stage,PSA level was decreased significantly after radiotherapy (Z =2.900,2.794,2.510,2.090,P<0.05).However,there was no statistically significant difference for the metastatic group (P> 0.05).Conclusions Ultra-hypofractionated stereotactic body radiotherapy is a safe and effective treatment for patients with prostate cancer.

7.
Chinese Journal of Radiation Oncology ; (6): 504-508, 2018.
Article in Chinese | WPRIM | ID: wpr-708224

ABSTRACT

Objective To analyze the correlation between treatment time and radiotherapy plan of deep inspiration breath-hold (DIBH) technique for the whole breast irradiation (WBI) in the left breast cancer after breast-conserving surgery,verify the inter-fractional reproducibility of radiotherapy,observe the heart location and dosimetric changes and calculate the effect of DIBH upon the WBI setup error after the surgery.Methods We prospectively enrolled 15 patients with left breast cancer undergoing WBI after breast-conserving surgery,who met the requirement of D1BH.Treatment time was recorded,its correlation with the number of field and monitor unit was analyzed.Inter-fractional setup errors and PTV delineation were calculated using cone beam CT (CBCT).The accuracy of the position and dose of the heart during radiotherapy was verified by the imaging fusion of CBCT and CT images.The variables among groups were analyzed by non-parametric Firedman test.Results The average treatment time of DIBH radiotherapy was 4.6 minutes.The treatment time was correlated with the maximal and total number of sub-fields and total monitor units.During DIBH treatment,the mean cardiac displacement volume was 19.1 cm3(3.8%).The mean cardiac dose difference between CBCT and planning CT was 5.1 cGy,and there was no significant difference in the heart V5-V30.The mean inter-fractional system setup error (∑) and random setup error (σ) in the left-right (x),superior-inferior (y) and anterior-posterior (z) direction were ∑x 1.9 mm,∑y 2.1 mm,∑z 2.0 mm,σx 1.3 mm,σy 1.3 mm,σz 1.4 mm,respectively.The corresponding minimal margins for setup error were 5.7 mm,6.2 mm and 6.0 mm,respectively.Conclusion DIBH for WBI after breast-conserving surgery does not significantly prolong the treatment time.Treatment time is related to treatment plan.DIBH yields high inter-fractional reproducibility and protects the heart.

8.
Chinese Journal of Radiological Medicine and Protection ; (12): 933-937, 2018.
Article in Chinese | WPRIM | ID: wpr-734301

ABSTRACT

Objective To analyze the radiation dose to the normal lung tissue of patients with early stage of non-small cell lung cancer treated by Cyberknife. Methods A retrospective analysis was conducted by summarizing the treatment plans of 264 patients with early stage non-small cell lung cancer from January 2011 to December 2013 in Tianjin Medical University Cancer Institute and Hospital. Sorted by the tumor volumes and locations, the Cyberknife plans were evaluated by means of dose volume histograms ( DVH) , homogeneity indexes ( HI) , percentage volumes receiving at least x Gy ( Vx ) of dose, i. e. , V5 , V10 , V20 , and V30 of the ipsilateral and contralateral lungs. For the tumors approximate to the hilus, the contralateral lungs were included in the optimization process, and the dose-volume metrics were analyzed for the contralateral and bilateral lungs. Results For the tumors close to the chest wall, V5≥(15. 21 ± 3. 12)% in ipsilateral lung tissue and V5≥(1. 34 ± 0. 67)% in contralateral lung tissue were observed. For the tumors near the hilus, V5≥(39. 4 ± 11. 90) % in ipsilateral lung tissue and V5≥(1. 48 ± 0. 34) % in contralateral lung tissue were observed. The irradiated volume ratios of both ipsilateral and contralateral lung tissue increased with the enlargement of tumor sizes. After including the contralateral lung tissue into the optimization, the irradiated volume ratios of the contralateral and bilateral lung tissue (V5,V10) decreasedsignificantly(t=2.44,4.81,3.53,3.17,P<0.05). Conclusions Higherriskof radiation injury in both ipsilateral and contralateral lung tissue can be expected for tumors near the hilus than near the chest wall. After including contralateral lung tissue into the planning optimization, lower dose to the contralateral and whole lung tissue was achieved, indicating a better protection of normal lung tissue.

9.
Chinese Journal of Radiological Medicine and Protection ; (12): 278-281, 2017.
Article in Chinese | WPRIM | ID: wpr-512100

ABSTRACT

Objective To evaluate the response rate and efficacy of Cyberknife in the treatment of iliac lymph node metastases (ILNM).Methods Twenty-two patients with 27 ILNM were treated by Cyberknife from May 2010 to May 2016.Tumor volume range from 0.88 to 125.66 cm3 (median 18.87 cm3).The total doses ranged from 21 to 51 Gy (median 39 Gy) and biological effective doses from 35.7 to 100 Gy (median 72.6 Gy) in 3-8 fractions (median 5).Sixty-four percent to eighty-two percent (median 72%) isodose line covered planning target.The survival rates were calculated by Kaplan-Meier method and compared with Log-rank test.Results Follow-up time ranged from 8 to 97 months (median 33 months).The complete response,partial response,stable disease and progression disease rates were 37%,48%,7.5%,48%,respectively.In addition,effective rate was 92.5%.Overall survival range from 4 to 68 months (median 21 months).The 1-,2-,3-year local control rate was all 90.6% and the survival rates were 78.8%,60.6% and 43.3%,respectively.Adverse reactions after treatment were gastrointestinal reactions such as nausea,vomiting,fatigue.The chemotherapy before Cyberknife helped to improve overall survival.The patients with backache or edema of lower extremity got rapid relief after treatment.Conclusion The treatment of ILNM with Cyberknife has provided a high response rate with minimal side effects.Cyberknife is a safe and effective local treatment method for ILNM.

10.
Chinese Journal of Microbiology and Immunology ; (12): 177-181, 2016.
Article in Chinese | WPRIM | ID: wpr-486216

ABSTRACT

Objective To develop a PCR-ELISA assay for the rapid, specific and sensitive detec-tion of human seasonal influenza virus ( H1, H3 and B) by using molecular biological and immunological methods in combination.Methods The primers were designed according to the genes encoding the matrix protein ( M) , the H1 and H3 hemagglutinin ( HA) of influenza A virus and the nonstructural proteins ( B-NS) of influenza B virus and then were labeled with biotin.The PCR products were detected by ELISA by use of an internal catching probe labeled with DIG.Results The minimum copy numbers of genes encoding the M, H1, H3 and B-NS proteins detected by the established assay were 1.43?103 , 8.67?102 , 3.86?103 and 5.45?103 copies/μl, respectively, which indicated that the PCR-ELISA assay was about 10 times more sensitive than agarose gel electrophoresis in the detection of PCR products.No cross-reactions between the different subtypes of influenza virus or different species of virus were observed.Moreover, a total of 104 clin-ical specimens of influenza virus were examined by the PCR-ELISA assay, the results of which were consist-ent with those of the virus isolation method.Conclusion The newly developed PCR-ELISA assay was a highly sensitive and specific method for the rapid detection and subtyping of influenza virus, suggesting the possibility of using it in laboratory for the surveillance and detection of influenza virus.

11.
Chinese Journal of Clinical and Experimental Pathology ; (12): 873-876, 2015.
Article in Chinese | WPRIM | ID: wpr-482735

ABSTRACT

Purpose To study the clinicopathological characteristics of primary pancreatic neuroendocrine neoplasms. Method 60 cases of resected pancreatic neuroendocrine neoplasms according to the WHO (2010) classification of the digestive system of neuroen-docrine tumor to evaluate morphological standard, and combining with the literature to discuss the clinicopathological characteristics. Results Among the 60 cases, 23 cases were male patients, the rest were females, with male and female ratio of 1 ∶ 1. 61. The age of the patients were ranged from 19 to 69 years, with mean age of 49. 38 ± 11. 60 years. Tumor maximum diameter ranged from 0. 5 to 16 cm, and the mean diameter was 3. 29 ± 3. 53 cm. 30 cases located in the pancreatic head, 27 cases in the body and end of the pancre-as and 3 cases in the neck. Pathological examination showed the G1 (24 cases), G2 (25 cases), G3 (9 cases), and mixed adenon-euroendocrine carcinoma ( MANEC) in 2 cases. Immunohistochemical staining showed that NSE, CgA, Syn, and CD56 were diffusely positive expression. 45 patients were followed up for 4~80 months, 7 cases died, of which 1 case was G2, 4 cases were G3, and 2 ca-ses were MANEC. Conclusion Primary pancreatic neuroendocrine neoplasms is a relatively rare pancreatic malignant tumor, and the diagnosis is based primarily on histologic features and immunohistochemical examination. Accurate pathological assessment has impor-tant value to guide clinical treatment and prognosis.

12.
Acta Pharmaceutica Sinica ; (12): 1305-8, 2015.
Article in Chinese | WPRIM | ID: wpr-505050

ABSTRACT

Three compounds were isolated from solid culture of endophyte Myrothecium roridum IFB-E091 in Artemisia annua. Their structures were determined as (S)-(-)-N-[2-(3-hydroxy-2-oxo-2,3-dihydro-1H-indol-3-yl)-ethyl]-acetamide (1), N-(4-hydroxyphenethyl)acetamide (2) and asperfumoid (3), in which compound 1 was a new indole derivative. In cytotoxicity assay, the compound 1 had no obvious inhibition activity in human hepatoma cell line SMMC-7721 and human cervical carcinoma cell line HeLa.

13.
Chinese Journal of Radiation Oncology ; (6): 392-394, 2015.
Article in Chinese | WPRIM | ID: wpr-467367

ABSTRACT

Objective To assess the efficacy and safety of CyberKnife radiotherapy in the treatment of locally advanced pancreatic carcinoma. Methods The data of 59 patients with locally advanced pancreatic carcinoma who were treated with CyberKnife radiotherapy from 2006 to 2014 were retrospectively analyzed. The tumor volume ranged from 13?? 0 cm3 to 125?? 1 cm3 with a median value of 27?? 1 cm3 . A dose of 35?50 Gy (median value= 45 Gy) in 3?8 fractions (median value = 5 fractions) was prescribed. The tumor progression was evaluated based on computed tomography. The overall survival (OS) and local progression?free survival ( LPFS) rates were calculated using the Kaplan?Meier method. Results The 1?and 2?year sample sizes were 26 and 17, respectively. The 1?and 2?year OS rates were 54% and 35%, respectively, while the 1?and 2?year LPFS rates were 91% and 70%, respectively. The median OS and LPFS times were 12?? 5 and 10?? 9 months, respectively. The overall incidence of grade 1?2 acute and late gastrointestinal toxicity was 61%. One patient with grade 3 late gastrointestinal toxicity had incomplete intestinal obstruction. Conclusions CyberKnife radiotherapy can achieve excellent treatment outcomes and mild complications in the treatment of locally advanced pancreatic carcinoma.

14.
Chinese Medical Journal ; (24): 232-238, 2014.
Article in English | WPRIM | ID: wpr-318007

ABSTRACT

<p><b>BACKGROUND</b>Spine is the most common site of bone metastases in patients with cancer. Conventional external beam radiotherapy lacks precision to allow delivery of large fraction radiation but simultaneously limit the dose to spinal cord. The purpose of this study was to evaluate the safety and efficacy of CyberKnife(®) radiation therapy for spinal metastases.</p><p><b>METHODS</b>Seventy-three lesions in 62 patients treated with CyberKnife radiotherapy from September 2006 to June 2010 for spinal metastases were retrospectively reviewed. Thirteen tumors in 12 patients had received prior radiation. Patients were followed clinically and radiographically for at least 12 months or until death. In all patients, the spinal cord and thecal sac were contoured for dose-volume constraints, and maximum doses to 0.1, 0.5, 1, 2, and 5-ml volumes were analyzed.</p><p><b>RESULTS</b>Using the CyberKnife System, 20-48 Gy in one to five fractions for unirradiated patients, and 21-38 Gy in one to five fractions for the previously irradiatied patients, were delivered. Median 2-Gy normalized Biological Equvalent Dose (nBED) of unirradiated targets and irradiated targets were 49.6 Gy10/2 (range, 31.25-74.8 Gy10/2) and 46.9 Gy10/2 (range, 29.8-66 Gy10/2), respectively. With a median follow-up of 9.4 months (range, 2.5-45 months), twenty-nine patients (46.7%) were alive, whereas the others died of progressive disease. Fifty-six patients (93.3%) reported complete or partial reduction of pain after CyberKnife radiotherapy at one-month follow-up, 17 patients (28.3%) reported some degree of pain relief after first fraction of the treatment course. Two patients experienced local recurrence at fifth and ninth months post-radiotherapy. Median maximum nBED for spinal cord and thecal sac of naive targets were 68.6 Gy2/2 (range, 8.3-154.5 Gy2/2) and 83.5 Gy2/2 (range, 10.5-180.5 Gy2/2), respectively. Median maximum nBED for spinal cord and thecal sac for the re-irradiated targets were 58.6 Gy2/2 (range, 17.7-140 Gy2/2) and 70.5 Gy2/2 (range, 21.7-141.3 Gy2/2), respectively. No patient developed radiation related myelopathy during the follow-up period.</p><p><b>CONCLUSION</b>Cyberknife radiotherapy is clinically effective and safe for spinal metastases, even in previously irradiated patients.</p>


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Neoplasm Recurrence, Local , Radiotherapy , Prospective Studies , Robotics , Methods , Spinal Neoplasms , Radiotherapy
15.
Chinese Journal of Radiation Oncology ; (6): 154-156, 2013.
Article in Chinese | WPRIM | ID: wpr-432190

ABSTRACT

Objective To evaluate quantitatively the extra absorbed dose generated by image guided system of the Cyberknife.Methods The exposure parameters and the average frequency of images acquisition during the treatments with G3 Cyberknife in 300 cases with various tumor locations and tracking modes were collected for analysis ;The measurements of the absorbed doses in the phantom with 5 points after single exposure generated by image guided system in various exposure parameters were performed with equipment of phantom CIRS Model 002LFC and 002 PRA with ion chamber PTW30010 included.Based on the data we collected andmeasured,the conclusion of how much extra absorbed dose generated by image guided system of Cyberknife the patients received during Cyberknife treatments was drawn.Results With an average fractions of 3.94(the median was 4),the average exposure frequency was 36.5 times for static tracking per patient per fraction,while it was 49.2 times for dynamic tracking.The experimental results with various exposure parameters,positions and tissue densities showed that the minimum absorbed dose after single exposure was 0.5 μGy,while the maximum was 385 μGy.Conclusions The image guided system of the Cyberknife can induce quite low absorbed dose in patient,while providing all three types of image guided function.

16.
Chinese Journal of Radiation Oncology ; (6): 36-38, 2013.
Article in Chinese | WPRIM | ID: wpr-432168

ABSTRACT

Objective To investigate the impacts of fiducial tracking and X-sight tracking on the short-term therapeutic effect of cybernikife in the treatment of lung cancer.Methods Retrospective analysis was performed on 64 lung cancer patients (72 lesions),including 40 primary tumor patients (41 lesions) and 24 metastatic tumor patients (31 lesions),who were treated with cyberknife.Fiducial tracking was used for 45 lesions,while X-sight tracking was used for 27 lesions.The planning target volume was covered by 70%-94% (median 80%) isodose contour.The irradiation dose was 60 Gy/3 fractions.The relationship between short-term therapeutic effect and tracking method was determined.Results Overall,the lesions undergoing fiducial tracking showed significantly higher response rate than those undergoing X-sight tracking (93% vs.74%,x2 =6.84,P=0.033),and so was in lower lung lesions (15% vs.7%,x2 =7.18,P=0.028).But the two tracking methods achieved similar effects in upper lung lesions (28% vs.12%,x2 =2.36,P =0.310).In the lesions with treatment volumes smaller than 15 cm3,the fiducial tracking achieved significantly higher response rate than the X-sight tracking (25 % vs.12%,x2 =6.53,P =0.038),but the two tracking methods achieved similar effects in the lesions with treatment volumes not smaller than 15 cm3 (17% vs 8%,x2 =1.57,P =0.460).Overall,the lesions undergoing X-sight tracking had significantly highertreatment failure rate than fiducial tracking (1 9 % vs.2 %,x2 =6.33,P =0.021).Conclusions Different tracking methods may lead to different therapeutic effects of cyberknife in the treatment of lung cancer,which are related to lesion location and treatment volume.

17.
Chinese Journal of Radiation Oncology ; (6): 214-216, 2012.
Article in Chinese | WPRIM | ID: wpr-425855

ABSTRACT

ObjectiveTo investigate the effectiveness and toxicity of CyberKnife in the treatment of lung metastases.MethodsTreatment details and outcomes were reviewed for 93 targets of 48 histologically verified patients treated by CyberKnife at the CyberKnife Center of Tianjin between September 2006 and June 2010.The median tumor volume was 6.0(0.2 - 135.2) cm3,the median biological equivalent dose was 140.8(53 - 180) cGy (α/β =10),the median fraction was 3(1-7) times and the median isodose line was 81% (71%-91% ).ResultsThe rate of follow-up is 96%.33 cases were followed up for more than 2years.The effective rate was 90.3%.Two targets of 2 patients locally progressed.The 1-and 2-year local control rates,overall survival (OS) rates and progression-free survival (PFS) rates were 98% and 98%,83% and 63%,and 64% and 37%,respectively.Univariate analyses showed that age older than 60 versus ≤60 years tended to be predictor for PFS ( x2 =3.45,P =0.063 ) ;The PFS of patients who had single lesion was better than patients with multiple lesions ( x2 =4.49,P =0.034 ) ; patients with disease-free interval longer than 18 months had better OS ( x2 =6.50,P =0.011 ).Five patients were reported to experience treatment-related grade 1 radiation pulmonary injury,and one each for subcutaneous fibrosis with pigmentation,grade 2 and grade 3 adverse event.ConclusionsFor patients with lung metastatic lesion,CyberKnife is an effective option with high local control rate and little acute reaction.The long-term outcome and toxicity need further study.

18.
Virologica Sinica ; (6): 292-298, 2012.
Article in Chinese | WPRIM | ID: wpr-424062

ABSTRACT

Currently,three predominant subtypes of influenza virus are prevalent in pig populations worldwide:H1N1,H3N2,and H1N2.European avian-like H1N1 viruses,which were initially detected in European pig populations in 1979,have been circulating in pigs in eastern China since 2007.In this study,six influenza A viruses were isolated from 60 swine lung samples collected from January to April 2011 in eastern China.Based on whole genome sequencing,molecular characteristics of two isolates were determined.Phylogenetic analysis showed the eight genes of the two isolates were closely related to those of the avian-like H1N1 viruses circulating in pig populations,especially similar to those found in China.Four potential glycosylation sites were observed at positions 13,26,198,277 in the HA1 proteins of the two isolates.Due to the presence of a stop codon at codon 12,the isolates contained truncated PB1-F2 proteins.In this study,the isolates contained 591Q,627E and 701N in the polymerase subunit PB2,which had been shown to be determinants of virulence and host adaptation.The isolates also had a D rather than E at position 92 of the NS1,a marker of mammalian adaptation.Both isolates contained the GPKV motif at the PDZ ligand domain of the 3' end of the NS1,a characteristic marker of the European avian-like swine viruses since about 1999,which is distinct from those of avian,human and classical swine viruses.The M2 proteins of the isolates have the mutation (S31N),a characteristic marker of the European avian-like swine viruses since about 1987,which may confer resistance to amantadine and rimantadine antivirals.Our findings further emphasize the importance of surveillance on the genetic diversity of influenza A viruses in pigs,and raise more concerns about the occurrence of cross-species transmission events.

19.
Journal of International Oncology ; (12): 54-56, 2012.
Article in Chinese | WPRIM | ID: wpr-418023

ABSTRACT

Cyberknife,a newly developed stereotactic operation platform in radiosurgery system,has many advantages such as accurate positioning,image-guided and hyperfractionated radiotherapy.It has made very good effect in the treatment of locally advanced pancreatic carcinoma.At the same time,it has been applied in the preoperation and postoperation treatment of pancreatic carcinoma,and the palliative treatment of metastatic pancreatic carcinoma.So it can be a very good option for patients with pancreatic carcinoma.

20.
Chinese Journal of Radiation Oncology ; (6): 193-196, 2011.
Article in Chinese | WPRIM | ID: wpr-415523

ABSTRACT

Objective To investigate the mobility of the lung tumors in order to guide the margin that CTV is to be expanded to PTV during stereotaetic radiotherapy for lung tumors.Methods Eighty-three lung tumom ineluded,in which 7 invaded the chest wall.1-2 gold marker(s)was/were implanted into or nearby the tumor.The motion of lung tumors in x(right-left),y(superior-inferior)and:(anterior-posterior)directions were measured via X-ray simulator system.One week later,1.25 mm thick of 16-slice spiral CT lung scan were taken.Apex,middle,and bottom of the lung were classified according to anatomic boderlines.Results No significant difference was detected among movements of apex,middle and bottom of the lung lesions in x axis direction((1.6±0.8),(2.6±1.1),(2.8±1.7)mm,respectively(F=1.76,P=0.179))and,y axis direction((2.0±1.3),(4.3±2.8),(4.0±2.0)mm,respectively(F=2.06,P=0.135))in 76 lesions of 63 patients.Significant differences were detected in:axis((2.7±0.8),(7.3±3.6),(12.0±5.3)mm(F=16.33,P=0.000)).The mobilities of the 7 lesions of 7 patients invading the chest wall were very small in all directions(0.9±0.7,0.7±0.7.and 2.0±0.6 mm,respectively).Motion amplitude did not correlate with the sex,age,height,weight and FEV1/FVC(r=-0.001-0.136.all P>0.05).Conclusions Motion amplitude of lung tumor due to breathing is associated with tumor loeation and status of chest wall invoivement.Identification of the mobile rules and the influencing factors is important for the internal margin set-up in lung tumor radiotherapy.

SELECTION OF CITATIONS